On increase of calculation accuracy at the problem of determining the chemical composition of a medium


Nazarov V.G.

2018, issue 2, P. 219-232


Abstract
In work the problem of a finding of a chemical composition of a homogeneous medium by a method of collimated multiple X-ray irradiation is considered. The question on possibility of increase of accuracy of the solution is thus studied by carrying out of several series of repeated measurements of passing radiation. It is shown that under some natural assumptions on measurement errors of passing radiation, the solution errors tend to zero with growth of number of the measurements fulfilled. Results of the calculations executed for concrete substance are shown by way of illustration.

Keywords:
radiography of a continuous medium, finding the chemical composition of a medium, singular value decomposition, calculation accuracy

Download the article (PDF-file)

References

[1] Sergei Osipov, Sergei Chakhlov, Andrey Batranin, Oleg Osipov, Van Bak Trinh, Juriy Kytmanov, “Theoretical study of a simplified implementation model of a dual-energy technique for computed tomography”, NDT and E International, 98, (2018), 63–69.
[2] S.P. Osipov, V.A. Udod, Yanzhao Wang, “Identification of Materials in X-Ray Inspections of Objects by the Dual-Energy Method”, Russian Journal of Nondestructive Testing, 53 (8), (2017), 568–587.
[3] V.A. Klimenov, S.P. Osipov, A.K. Temnik, “Identifikatsiya veshchestva ob”yekta kontrolya metodom dual’nykh energiy”, Defektoskopiya, 11, (2013), 40–50.
[4] V.G. Nazarov, “Metod singulyarnogo razlozheniya matritsy v zadache nakhozhdeniya khimicheskogo sostava sredy”, Sibirskiye elektronnyye matematicheskiye izvestiya, 14, (2017), 821–837.
[5] V.G. Nazarov, “Vybor optimal’nykh znacheniy energii izlucheniya v zadache nakhozhdeniya khimicheskogo sostava sredy”, Matematicheskoye modelirovaniye, 30, (2018), 91–102.
[6] D.S. Anikonov, A.E. Kovtanyuk, I.V. Prokhorov, Ispol’zovaniye uravneniya perenosa v tomografii, Logos, M., 2000.
[7] D.S. Anikonov, A.E. Kovtanyuk, I.V. Prokhorov, Transport Equation and Tomography, VSP, Utrecht-Boston, 2002.
[8] J.H. Hubbell, S.M. Seltzer, Tables of X–Ray Mass Attenuation Coefficients and Mass Energy Absorption Coefficients 1 Kev to 20 Mev for Elements Z = 1 to 92 and 48 Additional Substances of Dosimetric Interest, Preprint NISTIR-5632, Nat. Inst. of Standard and Technology, Gaithersburg, 1995.
[9] M.J. Berger, J.H. Hubbell, S.M. Seltzer, J. Chang, J.S. Coursey, R. Sukumar, D. S. Zucker, “XCOM: Photon Cross Section Database. National Institute of Standards and Technology. Gaithersburg. MD.”, 2005, http://www.physics.nist.gov/xcom.
[10] S.K. Godunov, A.G. Antonov, O.P. Kirilyuk, V.I. Kostin, Garantirovannaya tochnost’ resheniya sistem lineynykh uravneniy v evklidovykh prostranstvakh, Nauka. Sib. otd-niye, Novosibirsk, 1988.
[11] Dzh. Forsayt, M. Mal’kol’m, K. Mouler, Mashinnyye metody matematicheskikh vychisleniy, Mir, M., 1980.
[12] F.R. Gantmakher, Teoriya matrits, Nauka, M., 1988.

To content of the issue